Introducing the Lynx Distributor M10: Your Reliable DC Bus Bar Solution

Seamless Integration with Lynx DC System

The Lynx Distributor is expertly designed to connect batteries to the Lynx DC distribution system, offering a streamlined and efficient solution.

High Capacity and Safety Features

Boasting a 1000A capacity, the Lynx Distributor ensures robust performance. Its fuse-protected connections and LED indicators for blown fuses enhance safety and ease of maintenance.

Victron Lynx Distributor M8 versus Lynx Distributor M10: What's the Difference?

The primary difference between the Lynx Distributor M8 and M10 models lies in the connection ports. The M10 features larger left-hand positive and negative holes and two right-hand positive and negative bolts for connecting to another Lynx distribution system, such as the Lynx Power In, Lynx Distributor, Lynx Shunt, or Lynx Smart BMS. With the eventual discontinuation of the Lynx M8 versions, the M10 is the recommended choice for future-proofing your power distribution needs.

Smart Monitoring Compatibility

When connected to a Lynx Smart BMS, it offers the convenience of transmitting fuse status information, enabling effective system management.

User-Friendly Accessories

Included with a 40cm RJ10 cable to connect to anther compatible Lynx device. Note: MEGA fuses are sold separately.

Enhanced Visibility with the VictronConnect App

When connected to a Lynx Smart BMS you can view the fuse statuses via the VictronConnect App

Grab a Lynx Distributor today and upgrade your DC distribution system to the Victron Lynx standard.

Victron Energy Limited Warranty Policy


Victron Energy warrants its products to be free from defects in workmanship and materials for a period of 5 years from the date of purchase by the end user, with a maximum of 66 months from the Victron Energy invoice date. Exceptions on this are: lead acid batteries; 2 years from date of purchase by the end user, with a maximum of 30 months from the Victron Energy invoice date, Lithium-ion batteries; 3 years from date of purchase by the end user. In addition to this proof of correct battery usage is required when making a battery warranty claim.


During this period, Victron Energy will, at its option, repair or replace the defective product free of charge. The warranty does not include performing or reimbursing de‐installation, transportation and re‐installation. This warranty will be considered void if the unit has suffered any physical damage or alteration, either internally or externally, and does not cover damages arising from improper use like:
• Reverse of battery polarity.
• Inadequate connection.
• Mechanical shock or deformation.
• Contact with liquid or oxidation by condensation.
• Use in inappropriate environment (dust, corrosive vapor, humidity, high temperature, biological infestation...).
• Breakage or damage due to lightning.
• Connection terminals and screws destroyed or other damages, like overheat, due to insufficient tightening.
• For any electronical breakage except due to lightning (reverse polarity, over‐voltage due to external cause), the state ofthe internal control diode and of the inputs/output X and Y capacitors determine the warranty.


This warranty will not apply where the product has been misused, neglected, improperly installed, or repaired by anyone else than Victron Energy or one of its authorized Qualified Service Partners. In order to qualify for the warranty, the product must not be disassembled or modified.


Repair or replacement are our sole remedies and Victron Energy shall not be liable for damages, whether direct, incidental,special, or consequential, even caused by negligence or fault.


Victron Energy owns all parts removed from repaired products. Victron Energy uses new or reconditioned parts made by various manufacturers in performing warranty repairs and building replacement products. If Victron Energy repairs or replaces a part of a product, its warranty term is not extended. In case of replacement the new component has a warranty of 6 months, without effect on the initial warranty period. All remedies and the measure for damages are limited to the above. Victron Energy shall in no event be liable for consequential, incidental, contingent orspecial damages, even if having been advised of the probability of such damages. Any and all other warranties expressed or implied arising by law, course of dealing, course of performance, usage of trade or otherwise, including but not limited to implied warranties of merchantability and fitness for a particular purpose, are limited in duration to a period of two (2) years from the date of purchase.


Life Support Policy
As a general policy, Victron Energy, does not recommend the use of any of its products in life support applications where failure or malfunction of the Victron Energy's product can be reasonably expected to cause failure of the life support device or to significantly affect its safety or effectiveness. Victron Energy does not recommend the use of any of its products in direct patient care. Victron Energy will not knowingly sell its products for use in such applications unless it receives in writing assurances satisfactory to Victron Energy that the risks of injury or damage have been minimized, the customer assumes all such risks, and the Liability of Victron Energy is adequately protected under the circumstances.


As a product requires service, it must be brought back to the place of purchase. In case no contact can be taken with the merchant, or if he is either unable or not allowed to provide service, direct contact should be taken with Victron Energy.


Warranty on Repairs
The warranty period on products or on printed circuits boards repaired by Victron Energy as well as on printed circuit boards for replacement is 6 months from delivery by Victron Energy.


Transport
It is the responsibility of the sender to sufficiently package these products. The transport must be organized in a way to avoid any damage, especially when a single unit or heavy unit is sent.


Severability
If a part of the terms and conditions set out above is held invalid, void or unenforceable due to any particular national or international legislation, it shall not affect other parts of the terms and conditions remaining.


For Australia only
Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure.

Specifications

Feature Description
Power Voltage Range 9 - 60Vdc
Supported System Voltages 12, 24, or 48V
Reverse Polarity Protection Yes (Note 1)
Current Rating 1000Adc continuous
Power Consumption Max 100mA (with all LEDs illuminated) (Note 2)
Connections Busbar M10, Fuses M8
Cables 40 cm RJ10 cable (included) (Note 3 and 4)
Enclosure Material ABS
Enclosure Dimensions 290 x 170 x 80 mm
Unit Weight 2.2 kg
Busbar Material Tinned copper
Busbar Dimensions 8 x 30mm
Operating Temperature Range -40°C to +60°C
Storage Temperature Range -40°C to +60°C
Humidity Max. 95% (non-condensing)
Protection Class IP22

Notes:

  1. The RJ10 cable connection is not protected against reverse polarity.
  2. Powered from Lynx Shunt VE.Can or Lynx Smart BMS.
  3. Power from Lynx Shunt VE.Can or Lynx Smart BMS.
  4. Data can only be received by a Lynx Smart BMS.