Victron 24V 3000VA MultiPlus VE.Bus 24/3000/70-16 Inverter/Charger: Optimize Your Power with Seamless Integration and Smart Control

Discover the ultimate power solution with the Victron 24V 3000VA MultiPlus Inverter/Charger, designed for those who demand reliability and efficiency in their energy systems. Ideal for a wide range of applications, from off-grid homes to sophisticated marine setups, this inverter/charger ensures continuous power supply and smart energy management.

Dual AC Outputs for Uninterrupted Power and Energy Savings

The MultiPlus features two AC outputs for unparalleled flexibility. The main output provides no-break functionality, seamlessly taking over power supply in milliseconds during grid failure, ensuring no disruption to sensitive electronics. The second output activates with AC input, perfect for non-essential loads, preventing unnecessary battery discharge.

Expandable Power with Parallel Operation

Experience virtually unlimited power capabilities. The MultiPlus allows for parallel connection of up to six units, offering up to 25 kW / 30 kVA of output and impressive charging capacity. This feature is ideal for large-scale installations requiring substantial power without compromising on efficiency.

Advanced Three Phase Capability

For applications demanding three-phase power, configure three units for seamless three-phase output. Expand further with parallel connections for up to 75 kW / 90 kVA of inverter power, catering to the most demanding power needs with ease.

Intelligent Power Management with PowerControl and PowerAssist

Manage limited power sources smartly with PowerControl, setting maximum currents to prevent overloading of generators or shore supplies. PowerAssist enhances this by supplementing insufficient power with battery reserves, ensuring optimal power usage and battery charging.

Solar Energy Integration for Grid Independence

The MultiPlus excels in off-grid and grid-connected PV systems, maintaining AC power even during grid failures. Its compatibility with alternative energy systems makes it a cornerstone for sustainable energy solutions.

Advanced System Configuration and Monitoring

Configure your system quickly with DIP switches or advanced VE.Bus software for parallel and three-phase setups. For off-grid, grid-interactive, or self-consumption applications, specialized Assistants simplify setup, MK3 to USB Cable required (sold separately).

Comprehensive On-Site and Remote Monitoring Options

Stay informed and in control with multiple monitoring options, including the Multi Control Panel, Cerbo GX, Ekrano GX or remotely via smartphone (VE.Bus Smart Dongle required - sold separately), and VRM for easy system oversight and management from anywhere.

Remote System Access and Configuration

With an Ethernet-connected Cerbo GX or other GX devices, access and adjust your system settings remotely, ensuring your system is always optimized for your needs.

The Victron 24V 3000VA MultiPlus Inverter/Charger is more than just a power source; it's a versatile, efficient, and intelligent solution designed to meet the most demanding energy needs. Whether you're powering an off-grid home, a tiny house, or any application where reliable and integrated solar power is needed, the MultiPlus offers a seamless, powerful, and smart energy solution.

Victron Energy Limited Warranty Policy


Victron Energy warrants its products to be free from defects in workmanship and materials for a period of 5 years from the date of purchase by the end user, with a maximum of 66 months from the Victron Energy invoice date. Exceptions on this are: lead acid batteries; 2 years from date of purchase by the end user, with a maximum of 30 months from the Victron Energy invoice date, Lithium-ion batteries; 3 years from date of purchase by the end user. In addition to this proof of correct battery usage is required when making a battery warranty claim.


During this period, Victron Energy will, at its option, repair or replace the defective product free of charge. The warranty does not include performing or reimbursing de‐installation, transportation and re‐installation. This warranty will be considered void if the unit has suffered any physical damage or alteration, either internally or externally, and does not cover damages arising from improper use like:
• Reverse of battery polarity.
• Inadequate connection.
• Mechanical shock or deformation.
• Contact with liquid or oxidation by condensation.
• Use in inappropriate environment (dust, corrosive vapor, humidity, high temperature, biological infestation...).
• Breakage or damage due to lightning.
• Connection terminals and screws destroyed or other damages, like overheat, due to insufficient tightening.
• For any electronical breakage except due to lightning (reverse polarity, over‐voltage due to external cause), the state ofthe internal control diode and of the inputs/output X and Y capacitors determine the warranty.


This warranty will not apply where the product has been misused, neglected, improperly installed, or repaired by anyone else than Victron Energy or one of its authorized Qualified Service Partners. In order to qualify for the warranty, the product must not be disassembled or modified.


Repair or replacement are our sole remedies and Victron Energy shall not be liable for damages, whether direct, incidental,special, or consequential, even caused by negligence or fault.


Victron Energy owns all parts removed from repaired products. Victron Energy uses new or reconditioned parts made by various manufacturers in performing warranty repairs and building replacement products. If Victron Energy repairs or replaces a part of a product, its warranty term is not extended. In case of replacement the new component has a warranty of 6 months, without effect on the initial warranty period. All remedies and the measure for damages are limited to the above. Victron Energy shall in no event be liable for consequential, incidental, contingent orspecial damages, even if having been advised of the probability of such damages. Any and all other warranties expressed or implied arising by law, course of dealing, course of performance, usage of trade or otherwise, including but not limited to implied warranties of merchantability and fitness for a particular purpose, are limited in duration to a period of two (2) years from the date of purchase.


Life Support Policy
As a general policy, Victron Energy, does not recommend the use of any of its products in life support applications where failure or malfunction of the Victron Energy's product can be reasonably expected to cause failure of the life support device or to significantly affect its safety or effectiveness. Victron Energy does not recommend the use of any of its products in direct patient care. Victron Energy will not knowingly sell its products for use in such applications unless it receives in writing assurances satisfactory to Victron Energy that the risks of injury or damage have been minimized, the customer assumes all such risks, and the Liability of Victron Energy is adequately protected under the circumstances.


As a product requires service, it must be brought back to the place of purchase. In case no contact can be taken with the merchant, or if he is either unable or not allowed to provide service, direct contact should be taken with Victron Energy.


Warranty on Repairs
The warranty period on products or on printed circuits boards repaired by Victron Energy as well as on printed circuit boards for replacement is 6 months from delivery by Victron Energy.


Transport
It is the responsibility of the sender to sufficiently package these products. The transport must be organized in a way to avoid any damage, especially when a single unit or heavy unit is sent.


Severability
If a part of the terms and conditions set out above is held invalid, void or unenforceable due to any particular national or international legislation, it shall not affect other parts of the terms and conditions remaining.


For Australia only
Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure.

Specifications

MultiPlus 24/3000/70
PowerControl Yes
PowerAssist Yes
Transfer switch (A) 16
INVERTER  
Input voltage range (V DC) 19 – 33 V
Output Output voltage: 230 VAC ± 2%
Frequency: 50 Hz ± 0,1%^{(1)}
Cont. output power at 25°C (VA) (3) 3000
Cont. output power at 25°C (W) 2400
Cont. output power at 40°C (W) 2200
Cont. output power at 65°C (W) 1700
Peak power (W) 6000
Maximum efficiency (%) 94
Zero load power (W) 20
Zero load power in AES mode (W) 15
Zero load power in Search mode (W) 10
CHARGER  
AC Input Input voltage range: 187-265 VAC
Input frequency: 45 – 65 Hz
Power factor: 1
Charge voltage 'absorption' (V DC) 28.8
Charge voltage 'float' (V DC) 27.6
Storage mode (V DC) 26.4
Charge current house battery (A)^{(4)} 70
Charge current starter battery (A) 4
Battery temperature sensor Yes
GENERAL  
Auxiliary output (5) Yes (16A)
Programmable relay^{(6)} Yes
Protection (2) a - g
VE.Bus communication port For parallel and three phase operation, remote monitoring and system integration
General purpose com. port Yes
Remote on-off Yes
Common Characteristics Operating temp. range: -40 to +65°C (fan assisted cooling)
Humidity (non-condensing): max 95%
ENCLOSURE  
Common Characteristics Material & Colour: aluminium (blue RAL 5012)
Protection category: IP 21
Battery-connection Four M8 bolts (2 plus and 2 minus connections)
230 V AC-connection Screw terminals 13
mm^{2} (6 AWG)
Weight (kg) 18
Dimensions (hxwxd in mm) 362 x 258 x 218
STANDARDS  
Safety EN-IEC 60335-1, EN-IEC 60335-2-29, IEC 62109-1
Emission, Immunity EN 55014-1, EN 55014-2, EN-IEC 61000-3-2, EN-IEC 61000-3-3, IEC 61000-6-1, IEC 61000-6-2, IEC 61000-6-3
Road vehicles 12V and 24V models: ECE R10-4

1) Can be adjusted to 60 HZ. 120 V models available on request 3) Non-linear load, crest factor 3:1
2) Protection key: 4) Up to 25˚C ambient
a) output short circuit 5) Switches off when no external AC source available
b) overload 6) Programmable relay that can a.o. be set for general alarm,
c) battery voltage too high DC under voltage or genset start/stop function
d) battery voltage too low AC rating: 230 V/4A
e) temperature too high DC rating: 4 A up to 35 VDC, 1 A up to 60 VDC
f) 230 VAC on inverter output 7) A.o. to communicate with a Lithium Ion battery BMS
g) input voltage ripple too high