Victron Multi RS Solar 48/6000 Dual Tracker: A New Standard in Solar Energy Management

Elevate your energy system with the Victron Multi RS Solar 48/6000 Dual Tracker, the premier 48V 6000VA inverter/charger with a dual MPPT capable of 450V/100A. This innovative solution is designed for optimal flexibility and efficiency, ensuring your energy needs are met with precision across a variety of operating modes.

Versatile Operating Modes for Every Need

  • Hybrid Mode: Harness solar power to its fullest by storing excess energy in a battery for use at night or during peak demand, with the ability to supplement power from the battery when consumption exceeds grid capacity.
  • Backup Mode: Experience uninterrupted power with an automatic switch to backup during grid outages, keeping your critical systems running smoothly.
  • Off-Grid Mode: Gain complete independence with the ability to operate without any grid connection, perfect for remote locations.
  • Generator Mode: Optimize generator use by controlling run-hours and supplementing with battery power when demand outstrips generator capacity.

Advanced PowerControl and PowerAssist Features

Set maximum currents for your grid or generator to prevent overloads with the PowerControl function. The Multi RS Solar takes it a step further with PowerAssist, supplementing insufficient power with battery reserves during peak demand and recharging the battery when the load decreases.

Dual MPPT for Maximum Solar Harvesting

With dual MPPT, the Multi RS Solar 48/6000 ensures that you're capturing the maximum energy from your solar panels, even in varying lighting conditions. This feature allows for two independent solar arrays, optimizing energy harvest and providing redundancy.

Intuitive Monitoring with Display, Bluetooth, and VictronConnect App

Keep a close eye on your system's health with the integrated display showing battery, inverter, and solar parameters. For remote monitoring and control, the VictronConnect app pairs seamlessly with your device via Bluetooth.

Scalable PV Capacity

Your solar capacity grows with you. Start with the integrated 6 kWp PV capacity and expand by adding solar chargers for AC or DC coupling. Integrate additional PV Inverters with automatic power control for a tailored energy solution.

Robust Communication and Connection Options

Monitor, log data, and update firmware remotely via VE.Can connection to a GX device. For remote monitoring, connect with VE.Direct to a GlobalLink 520. Programmable relays, temperature sensors, and voltage sensors ensure a customizable and secure setup.

The Victron Multi RS Solar 48/6000 Dual Tracker is not just an inverter/charger—it's the heart of your solar energy system. It's designed to adapt to your changing power needs while providing efficiency and reliability. Step into the future of energy management and make the smart move to a system that grows with your energy demands.

Victron Energy Limited Warranty Policy


Victron Energy warrants its products to be free from defects in workmanship and materials for a period of 5 years from the date of purchase by the end user, with a maximum of 66 months from the Victron Energy invoice date. Exceptions on this are: lead acid batteries; 2 years from date of purchase by the end user, with a maximum of 30 months from the Victron Energy invoice date, Lithium-ion batteries; 3 years from date of purchase by the end user. In addition to this proof of correct battery usage is required when making a battery warranty claim.


During this period, Victron Energy will, at its option, repair or replace the defective product free of charge. The warranty does not include performing or reimbursing de‐installation, transportation and re‐installation. This warranty will be considered void if the unit has suffered any physical damage or alteration, either internally or externally, and does not cover damages arising from improper use like:
• Reverse of battery polarity.
• Inadequate connection.
• Mechanical shock or deformation.
• Contact with liquid or oxidation by condensation.
• Use in inappropriate environment (dust, corrosive vapor, humidity, high temperature, biological infestation...).
• Breakage or damage due to lightning.
• Connection terminals and screws destroyed or other damages, like overheat, due to insufficient tightening.
• For any electronical breakage except due to lightning (reverse polarity, over‐voltage due to external cause), the state ofthe internal control diode and of the inputs/output X and Y capacitors determine the warranty.


This warranty will not apply where the product has been misused, neglected, improperly installed, or repaired by anyone else than Victron Energy or one of its authorized Qualified Service Partners. In order to qualify for the warranty, the product must not be disassembled or modified.


Repair or replacement are our sole remedies and Victron Energy shall not be liable for damages, whether direct, incidental,special, or consequential, even caused by negligence or fault.


Victron Energy owns all parts removed from repaired products. Victron Energy uses new or reconditioned parts made by various manufacturers in performing warranty repairs and building replacement products. If Victron Energy repairs or replaces a part of a product, its warranty term is not extended. In case of replacement the new component has a warranty of 6 months, without effect on the initial warranty period. All remedies and the measure for damages are limited to the above. Victron Energy shall in no event be liable for consequential, incidental, contingent orspecial damages, even if having been advised of the probability of such damages. Any and all other warranties expressed or implied arising by law, course of dealing, course of performance, usage of trade or otherwise, including but not limited to implied warranties of merchantability and fitness for a particular purpose, are limited in duration to a period of two (2) years from the date of purchase.


Life Support Policy
As a general policy, Victron Energy, does not recommend the use of any of its products in life support applications where failure or malfunction of the Victron Energy's product can be reasonably expected to cause failure of the life support device or to significantly affect its safety or effectiveness. Victron Energy does not recommend the use of any of its products in direct patient care. Victron Energy will not knowingly sell its products for use in such applications unless it receives in writing assurances satisfactory to Victron Energy that the risks of injury or damage have been minimized, the customer assumes all such risks, and the Liability of Victron Energy is adequately protected under the circumstances.


As a product requires service, it must be brought back to the place of purchase. In case no contact can be taken with the merchant, or if he is either unable or not allowed to provide service, direct contact should be taken with Victron Energy.


Warranty on Repairs
The warranty period on products or on printed circuits boards repaired by Victron Energy as well as on printed circuit boards for replacement is 6 months from delivery by Victron Energy.


Transport
It is the responsibility of the sender to sufficiently package these products. The transport must be organized in a way to avoid any damage, especially when a single unit or heavy unit is sent.


Severability
If a part of the terms and conditions set out above is held invalid, void or unenforceable due to any particular national or international legislation, it shall not affect other parts of the terms and conditions remaining.


For Australia only
Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure.

Specifications

Model Multi RS Solar 48/6000 Dual Tracker
PowerControl & PowerAssist Yes
Transfer switch 50 A
Maximum AC input and pass-through current 50 A
INVERTER  
DC Input voltage range (1) 38 – 62 V
AC Output (2) Output voltage: 230 VAC ± 2 %
Frequency: 50 Hz ± 0,1 %
Maximum continuous inverter current: 25 Aac
Continuous output power at 25 °C Increases linearly from 4800 W at 46 VDC
to 5300 W at 52 VDC
Continuous output power at 40 °C 4500 W
Continuous output power at 65 °C 3000 W
Peak power (3) 9 kW for 3 seconds
7 kW for 4 minutes
Short-circuit output current 45 A
Max. AC output overcurrent protection 30 A
Efficiency 96.5 % at 1 kW load
94 % at 5 kW load
Zero load power consumption 20 W
Low Battery shutdown 37.2 V (adjustable)
Low battery restart 43.6 V (adjustable)
SOLAR  
Maximum open circuit PV array voltage^{(4)} 450 V
Start-up voltage 120 V
MPPT operating voltage range 80 – 450 V
Maximum operational PV input current limit 13 A
Maximum PV conversion power 6 kW total – 3 kW per tracker
Maximum PV short circuit current 16 A
Earth leakage trip level 30 mA
Isolation fail level (detection before start-up) 100 kΩ
CHARGER  
AC Input Nominal Voltage: 230 VAC, Input voltage range: 187-265 VAC
Nominal frequency: 50 Hz, Input frequency: 45-65 Hz
AC inrush current: NA
Programmable charge voltage range (5) 36 – 60 V
Charge voltage 'absorption' Default setting: 57.6 V (adjustable)
Charge voltage 'float' Default setting: 55.2 V (adjustable)
Maximum charge current from AC (6) 88 A @ 57.6 VDC
Total maximum charge current (AC + PV) 100 A DC
Battery temperature sensor Included
Battery voltage sense Yes
GENERAL  
Auxiliary output (AC-out-2) (7) Yes
3-phase and parallel operation 3-phase support with one unit per phase. Parallel not supported.
Programmable relay (8) Yes
Protections (9) a - g
Data communications ports (10) VE.Direct, VE.Can & Bluetooth
Bluetooth frequency & power 2402 - 2480 Mhz, 4 dBm
Programmable analog/digital input/output ports Yes, 2x
Remote on-off Yes
Operating temperature range -40 to +65 °C (fan assisted cooling)
Maximum altitude 2000 m
Humidity (non-condensing) max 95 %
ENCLOSURE  
Material & Colour steel, blue RAL 5012
Protection category IP21 Protective Class: I
Battery-connection M8 bolts
PV Connection 2 strings, each with positive and negative MC4
230 VAC-connection Screw terminals 10 mm² (6 AWG)
Weight 12.3 kg
Dimensions (hxwxd) 425 x 460 x 125 mm
STANDARDS  
Safety EN-IEC 60335-1, EN-IEC 60335-2-29, EN-IEC 62109-1, EN-IEC 62109-2
Emission, Immunity EN 55014-1, EN 55014-2, EN-IEC 61000-3-2, EN-IEC 61000-3-3, IEC 61000-6-1, IEC 61000-6-2,
IEC 61000-6-3, Pollution Degree 2
Overvoltage Category Battery: OVC 1, PV port: OVC II, AC in / AC out: OVC III
1) Minimum start-up voltage is 41 VDC. Over-voltage disconnect: 65,5 V.
2) Can be adjusted to 240 VAC and 60 Hz
3) Peak power capacity and duration depends on start temperature of heatsink.
Mentioned times are with cold unit.
4) The maximum PV voltage should not exceed 8x battery float voltage.
If for example the float voltage of the battery is 50 V,
the maximum PV voltage should not exceed 8 x 50 = 400 V.
5) The Charger set points (float & absorption) can be set to max 60 V.
The output voltage at the charger terminals can be higher due to compensation
for temperature & voltage drop over the battery cables.
The maximum output current is reduced on a linear basis from full current at 60 V to
5 A at 62 V. The equalization voltage can be set to max 62 V, the equalization current
percentage can be set to max 6 %.
6) The maximum charge current from AC sources depends on input voltage and battery current. At 230V input and 57.6V battery voltage, and 25C ambient, the maximum charge
current is 88 A. See manual, limitations section, for further details.
7) AC-out-2 is connected directly to the AC input and intended for non-critical loads. The AC-out-2 load is taken into account by PowerControl & PowerAssist.
8) Programmable relay which can be set for general alarm, DC under voltage or genset start/stop function. DC rating: 4 A up to 35 VDC and 1 A up to 70 VDC
9) Protection key: a) output short circuit b) overload c) battery voltage too high d) battery voltage too low e) temperature too high f) 230 VAC on inverter output g) solar
earth leakage.
10) Not currently compatible with VE.Smart Networks. Connection to a GX device (i.e. Cerbo GX) must be made via the VE.Can interface. The VE.Direct interface is for connection to
the GlobalLink 520.