Victron Skylla-i Control GX (Right Angle RJ45)
VE.Can Remote Panel with Real-Time Display and Auto Brightness Control
Victron Temperature Sensor Type C (Inverter RS ...DESCRIPTION
Victron Skylla-i Control GX: Precision Remote Management for Skylla-i Chargers
Centralised Monitoring and Control for Marine, Industrial, and Off-Grid Power Systems
The Victron Skylla-i Control GX is a dedicated remote panel engineered to provide comprehensive oversight of your Skylla-i battery charger. Designed for seamless integration via the VE.Can communication bus, this panel delivers real-time data and intuitive control, making it an essential component for professional installations where reliable battery management is critical.
Whether you are managing a single charger or a synchronised parallel bank, the Skylla-i Control GX consolidates key parameters into one accessible interface. It is particularly suited to marine electrical systems, industrial backup power, and off-grid energy setups where precise charging data and remote on/off capability enhance operational efficiency.
Real-Time System Visibility
Stay informed with a clear three-digit LED display that cycles through essential metrics: charge current, battery voltage, input current, and input current limit. All readings are presented in SI units (Amperes or Volts) with one decimal digit for accuracy, automatically adjusting when the charger operates at or above 100 A. This level of detail allows operators to verify charging performance at a glance, reducing the need for manual inspections in hard-to-reach installations.
Intelligent Design for Demanding Environments
The panel features an automatic LED brightness adjustment via an integrated light sensor, ensuring optimal visibility in both bright engine rooms and dimly lit control cabins. The status LEDs clearly indicate charging stages—bulk, absorption, and float—so you can monitor progress without navigating menus. A rotary select/adjust knob and dedicated on/off button provide tactile, straightforward control, even when wearing gloves.
Installation is simplified with a metal mounting frame and included screws, while the right-angle RJ45 connector minimises cable strain in tight spaces. The panel connects using standard UTP (Unshielded Twisted Pair) cable with RJ45 connectors, and two internally linked RJ45 sockets support daisy-chaining or bus termination with the supplied terminators.
Key Features
- VE.Can communication for reliable data exchange with all Skylla-i chargers
- Real-time display of charge current, battery voltage, input current, and input current limit
- Automatic LED brightness control via light sensor for varied lighting conditions
- Master on/off control for connected chargers with a single button press
- Multi-panel support – connect several panels to one charger or a synchronised parallel group
- Right-angle RJ45 connector for space-constrained installations
- Supplied with bus terminators and metal mounting frame for straightforward setup
Seamless Integration with Victron Skylla-i Chargers
Compatible with both 1-output and 3-output Skylla-i models, this control panel extends the functionality of your charging system without complex configuration. The VE.Can bus ensures robust, noise-immune communication over standard network cable, a proven solution in professional marine and industrial environments. Multiple panels can be connected to a single charger or a set of synchronised parallel chargers, allowing monitoring from different locations—ideal for large vessels or multi-room facilities.
Built for Professional Applications
The Skylla-i Control GX addresses common challenges in remote charger management: inaccessible charger locations, the need for consolidated data, and the risk of incorrect settings. By providing a dedicated interface, it reduces the likelihood of battery damage from improper charging and simplifies troubleshooting. The compact dimensions (65 x 120 x 40 mm) allow flush mounting in standard panels, while the robust metal frame withstands vibration and temperature fluctuations typical of engine rooms and industrial sites.
Take Command of Your Charging System
Enhance the control and visibility of your Victron Skylla-i charger with the Skylla-i Control GX. Whether you are outfitting a new build or retrofitting an existing installation, this remote panel delivers the precision and reliability expected from Victron Energy. Add the Skylla-i Control GX to your system today and experience centralised power management at your fingertips.
SKU: VIC-REC000300010R
SPECIFICATIONS
Specifications
| Model | Skylla-i Control GX (90º RJ45) |
|---|---|
| Part Number | REC000300010R |
| Product Type | Remote Panel |
| Compatible Chargers | All Skylla-i chargers |
| Communication Bus | VE.CAN bus |
| Connection Cable | Regular UTP (Unshielded Twisted Pair) cable with two RJ45 connectors |
| RJ45 Sockets | Two RJ45 sockets which are internally connected |
| RJ45 Bus Terminators | Comes complete with both RJ45 bus terminators |
| Display Parameters | Charge current; battery voltage; input current; input current limit |
| Display Units | SI units (Ampere or Volts) with one decimal digit |
| Decimal Display Behaviour | The decimal digit disappears when the charger operates at or above 100 A |
| LED Brightness Control | Controlled automatically using a light sensor |
| Charger On/Off Control | Switched on and off by briefly pressing the on|off button |
| Multi-Panel Support | Several Skylla-i control panels can be connected to one charger or to a set of synchronized and parallel connected chargers |
| Default Device Instance | Zero |
| Dimensions (H x W x D) | 65 x 120 x 40 mm |
| SKU: | VIC-REC000300010R |
| Barcode: | 8719076024316 |
| Model #: | REC000300010R |
| MPN: | REC000300010R |
WARRANTY
Victron Energy Limited Warranty Policy
Victron Energy warrants its products to be free from defects in workmanship and materials for a period of 5 years from the date of purchase by the end user, with a maximum of 66 months from the Victron Energy invoice date. Exceptions on this are: lead acid batteries; 2 years from date of purchase by the end user, with a maximum of 30 months from the Victron Energy invoice date, Lithium-ion batteries; 3 years from date of purchase by the end user. In addition to this proof of correct battery usage is required when making a battery warranty claim.
During this period, Victron Energy will, at its option, repair or replace the defective product free of charge. The warranty does not include performing or reimbursing de‐installation, transportation and re‐installation. This warranty will be considered void if the unit has suffered any physical damage or alteration, either internally or externally, and does not cover damages arising from improper use like: • Reverse of battery polarity. • Inadequate connection. • Mechanical shock or deformation. • Contact with liquid or oxidation by condensation. • Use in inappropriate environment (dust, corrosive vapor, humidity, high temperature, biological infestation...). • Breakage or damage due to lightning. • Connection terminals and screws destroyed or other damages, like overheat, due to insufficient tightening. • For any electronical breakage except due to lightning (reverse polarity, over‐voltage due to external cause), the state ofthe internal control diode and of the inputs/output X and Y capacitors determine the warranty.
This warranty will not apply where the product has been misused, neglected, improperly installed, or repaired by anyone else than Victron Energy or one of its authorized Qualified Service Partners. In order to qualify for the warranty, the product must not be disassembled or modified.
Repair or replacement are our sole remedies and Victron Energy shall not be liable for damages, whether direct, incidental,special, or consequential, even caused by negligence or fault.
Victron Energy owns all parts removed from repaired products. Victron Energy uses new or reconditioned parts made by various manufacturers in performing warranty repairs and building replacement products. If Victron Energy repairs or replaces a part of a product, its warranty term is not extended. In case of replacement the new component has a warranty of 6 months, without effect on the initial warranty period. All remedies and the measure for damages are limited to the above. Victron Energy shall in no event be liable for consequential, incidental, contingent orspecial damages, even if having been advised of the probability of such damages. Any and all other warranties expressed or implied arising by law, course of dealing, course of performance, usage of trade or otherwise, including but not limited to implied warranties of merchantability and fitness for a particular purpose, are limited in duration to a period of two (2) years from the date of purchase.
Life Support Policy As a general policy, Victron Energy, does not recommend the use of any of its products in life support applications where failure or malfunction of the Victron Energy's product can be reasonably expected to cause failure of the life support device or to significantly affect its safety or effectiveness. Victron Energy does not recommend the use of any of its products in direct patient care. Victron Energy will not knowingly sell its products for use in such applications unless it receives in writing assurances satisfactory to Victron Energy that the risks of injury or damage have been minimized, the customer assumes all such risks, and the Liability of Victron Energy is adequately protected under the circumstances.
As a product requires service, it must be brought back to the place of purchase. In case no contact can be taken with the merchant, or if he is either unable or not allowed to provide service, direct contact should be taken with Victron Energy.
Warranty on Repairs The warranty period on products or on printed circuits boards repaired by Victron Energy as well as on printed circuit boards for replacement is 6 months from delivery by Victron Energy.
Transport It is the responsibility of the sender to sufficiently package these products. The transport must be organized in a way to avoid any damage, especially when a single unit or heavy unit is sent.
Severability If a part of the terms and conditions set out above is held invalid, void or unenforceable due to any particular national or international legislation, it shall not affect other parts of the terms and conditions remaining.
For Australia only Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure.
Exotronic provides high-quality products and solutions tailored for B2B and commercial customers, including commercial businesses, caravan manufacturers, marine electricians, OEMs, as well as emergency services, and more.