website

Enerdrive Replacement Temp Sensor ePower AC & DC Chargers

Essential thermal monitoring for safe and optimised battery charging


Notify me when available

You have already submited form for Default Title

Thanks for contacting us. We'll get back to you as soon as product / variant is back in stock.
4

DESCRIPTION

Enerdrive EN3-TEMP Replacement Temperature Sensor: Advanced Thermal Monitoring

Essential Protection for Your 12V and 24V Battery Systems

Maintaining the correct charging voltage is critical for battery health, and this requirement is highly dependent on ambient and internal battery temperatures. The Enerdrive Replacement Temp Sensor for ePOWER AC and DC Chargers provides real-time thermal data directly to your charging unit. By relaying precise temperature readings, this sensor enables your power system to dynamically adjust its output voltage, ensuring an optimal charge profile regardless of the environmental conditions.

Whether you are touring the Australian outback or navigating coastal waters, temperature fluctuations can severely impact battery performance. A dedicated thermal charger setup relies on accurate sensor feedback to function safely. This replacement component restores full functionality to your ePOWER system, protecting your deep cycle batteries from potential damage caused by incorrect voltage application.

How Temperature Compensation Protects Your Investment

Batteries are highly sensitive to heat and cold. Without temperature compensation, a charger will output a fixed voltage based on an assumed standard temperature, typically around 25 degrees Celsius. In elevated temperatures, this fixed voltage is too high, leading to overcharging, excessive outgassing, and the dangerous potential for thermal runaway. Conversely, in cold environments, the standard voltage is too low, resulting in undercharging and premature capacity loss through sulfation.

By installing this replacement sensor, your Enerdrive charger receives the exact thermal metrics required to adjust its charging algorithms automatically. The system lowers the voltage when the battery is hot to prevent damage and increases the voltage when the battery is cold to ensure a complete and thorough charge. This intelligent thermal monitoring significantly extends the functional lifespan of expensive battery banks.

Rugged Design with Secure Battery Post Mounting

Designed for the demanding conditions of off-grid mobile and marine setups, this sensor is built for reliability in harsh environments. It features a high-quality coiled grey cable that allows for flexible routing and neat installation within tight battery compartments. The coiled design effectively reduces slack and prevents the cable from catching on other internal components.

At the sensor end, a heavy-duty metal ring terminal lug ensures a secure, high-conductivity connection directly to the battery terminal post. Direct post mounting is crucial because it provides the most accurate measurement of the actual battery core temperature, rather than just the ambient air temperature within the battery box. This precision is what makes the sensor highly effective for advanced charging applications.

Key Features of the Enerdrive Replacement Temp Sensor

  • Direct compatibility with the Enerdrive ePOWER range of AC and DC battery chargers
  • Robust metal ring terminal lug for highly accurate, direct-to-post thermal readings
  • Durable coiled cable design to reduce clutter and allow flexible installation routing
  • Enables dynamic voltage adjustments to optimise charging efficiency in extreme climates
  • Reduces the risk of thermal runaway, dangerous outgassing, and chronic undercharging
  • Essential for maximising the operational lifespan of AGM, Gel, and traditional lead-acid battery banks

Restore Your ePOWER System to Peak Performance

A damaged, severed, or missing temperature sensor forces your charger to default to a standard profile, immediately compromising system efficiency and battery safety. Replacing a faulty unit is a simple yet critical maintenance step for any serious 4WD, caravan, or marine power system. The EN3-TEMP is engineered to the exact specifications of your original equipment, ensuring seamless integration and immediate restoration of vital thermal monitoring capabilities.

Protect your battery bank and ensure your power system operates at peak efficiency during your next off-grid adventure. Upgrade or replace your current setup with the Enerdrive Replacement Temp Sensor today and maintain complete confidence in your power management system.


SKU: EN3-TEMP

SPECIFICATIONS

Specifications

Enerdrive Part #EN3-TEMP
DescriptionReplacement Temperature Sensor to Suit ePOWER Chargers
ApplicationePOWER and DC-DC Battery Chargers
Battery Temp Sensor Port (ePOWER AC Chargers)RJ12 (standard battery temp. sensor supplied)
Battery Temperature Sensor Port (DC-DC Battery Chargers)RJ12 (optional)
Cable Length7.5 Meter Cable
Battery ConnectionRing terminals to the negative terminal of the main battery bank
Recommended InstallationInstalled on the main battery bank at the negative terminal - Bank one
Battery Charging Voltage Adjustment from 25 °C normal setting (Flooded and GEL type)< 25 °C: + 0.027 V /°C; 25°C: 0 V; > 25 °C: -0.027 V /°C
Battery Charging Voltage Adjustment from 25 °C normal setting (AGM type)< 25 °C: + 0.021 V /°C; 25°C: 0 V; > 25 °C: - 0.021 V /°C

SKU: EN3-TEMP
Model #: EN3-TEMP
MPN: EN3-TEMP

Exotronic provides high-quality products and solutions tailored for B2B and commercial customers, including commercial businesses, caravan manufacturers, marine electricians, OEMs, as well as emergency services, and more.