Victron 1000A Lynx Shunt VE.Can M8 Battery Monitor
1000A Intelligent Battery Monitor with Integrated Busbar & Fuse Holder
Victron 300A Smart Shunt (SmartShunt) Bluetooth...DESCRIPTION
Victron Lynx Shunt VE.Can M8: High-Capacity 1000A Battery Monitoring
The Victron Lynx Shunt VE.Can M8 represents a critical upgrade for high-capacity power management systems. Operating as a highly accurate 1000A battery monitor, this device calculates your exact battery state of charge while functioning as a central distribution node. By integrating heavy-duty busbars and a main system fuse holder into a single robust enclosure, it significantly streamlines your electrical architecture.
Designed specifically for complex 12V, 24V, and 48V setups, this shunt eliminates the clutter and voltage drops commonly associated with daisy-chained cables. It is the perfect backbone for marine vessels, off-grid solar systems, and large-scale RV builds requiring professional-grade energy monitoring.
Seamless GX Device Communication
Equipped with a VE.Can communication interface, the shunt transmits real-time battery data directly to your Victron Cerbo GX or Ekrano GX. This enables comprehensive monitoring of your battery voltage, current draw, and overall state of charge through the Victron Remote Management (VRM) portal or a local GX Touch screen. The package includes two RJ45 VE.Can terminators, ensuring a clean and reliable data connection right out of the box.
Integrated Busbar and Fuse Holder
Unlike standalone battery monitors, this unit combines precise measurement with high-current power distribution. It features massive 8 x 30 mm tinned copper busbars, engineered to handle a 1000Adc continuous current without significant heat generation or power loss. Furthermore, the enclosure includes a dedicated space to mount a CNN main system fuse (purchased separately) directly onto the M8 studs. This design reduces the number of connections in your high-current path, lowering resistance and minimising potential failure points.
A Core Component of the Lynx Ecosystem
As a central piece of the modular Lynx Distribution System, the unit connects directly to the Lynx Power In or Lynx Distributor modules. This modular approach allows you to build a neat, scalable, and fully protected DC distribution system. A power-indicating LED is built directly into the unit, providing immediate visual feedback on system status.
Key Features
- Rated for an impressive 1000Adc continuous current, supporting large battery banks and heavy inverter loads
- Compatible with 12V, 24V, and 48V power systems for maximum versatility
- Built-in holder for a CNN series fuse, streamlining overcurrent protection
- Heavy-duty M8 stainless steel connection studs and 8 x 30 mm tinned copper busbars
- Direct VE.Can integration via RJ45 ports for advanced GX device communication
- Includes connections for an external temperature sensor and a potential-free alarm contact
Engineered for Reliability
Constructed with a durable ABS enclosure, the unit is rated to IP22, offering protection in controlled electrical compartments. It operates flawlessly in extreme conditions, supporting a temperature range from -40 to +60 degrees Celsius. Whether you are running a high-demand air conditioning unit on a superyacht or powering a remote off-grid homestead, this shunt provides the precise data and robust physical connections required to keep your system safe.
Upgrade Your Power Management
Take control of your battery data and simplify your wiring architecture. Order the Victron Lynx Shunt VE.Can M8 today to ensure your off-grid or marine energy system operates with absolute precision and safety.
SKU: VIC-LYN040102100
SPECIFICATIONS
Specifications
| Power Supply | |
| Voltage Range | 9 - 70 Vdc |
| Supported System Voltages | 12, 24, or 48V |
| Reverse Polarity Protection | No |
| Current Rating | |
| Continuous | 1000Adc |
| Power Consumption | |
| At 12V | 60mA |
| At 24V | 33mA |
| At 48V | 20mA |
| Potential Free Alarm Contact | 3A, 30Vdc, 250Vac |
| Connections | |
| Busbar | M8 |
| Fuse | M8 |
| VE.Can | RJ45 and RJ45 terminator |
| Power Supply Connection | to Lynx Distributor RJ10 (a RJ10 cable ships with each Lynx Distributor) |
| Temperature Sensor | Screw terminal |
| Relay | Screw terminal |
| Physical Attributes | |
| Enclosure Material | ABS |
| Dimensions (h x w x d) | 190 x 180 x 80 mm |
| Unit Weight | 1.4 kg |
| Busbar Material | Tinned copper |
| Busbar Dimensions (hxw) | 8 x 30 mm |
| Environmental Conditions | |
| Operating Temperature Range | -40°C to +60°C |
| Storage Temperature Range | -40°C to +60°C |
| Humidity | Max. 95% (non-condensing) |
| Protection Class | IP22 |
| SKU: | VIC-LYN040102100 |
| Barcode: | 8719076022602 |
| Model #: | LYN040102100 |
| MPN: | LYN040102100 |
WARRANTY
Victron Energy Limited Warranty Policy
Victron Energy warrants its products to be free from defects in workmanship and materials for a period of 5 years from the date of purchase by the end user, with a maximum of 66 months from the Victron Energy invoice date. Exceptions on this are: lead acid batteries; 2 years from date of purchase by the end user, with a maximum of 30 months from the Victron Energy invoice date, Lithium-ion batteries; 3 years from date of purchase by the end user. In addition to this proof of correct battery usage is required when making a battery warranty claim.
During this period, Victron Energy will, at its option, repair or replace the defective product free of charge. The warranty does not include performing or reimbursing de‐installation, transportation and re‐installation. This warranty will be considered void if the unit has suffered any physical damage or alteration, either internally or externally, and does not cover damages arising from improper use like:
• Reverse of battery polarity.
• Inadequate connection.
• Mechanical shock or deformation.
• Contact with liquid or oxidation by condensation.
• Use in inappropriate environment (dust, corrosive vapor, humidity, high temperature, biological infestation...).
• Breakage or damage due to lightning.
• Connection terminals and screws destroyed or other damages, like overheat, due to insufficient tightening.
• For any electronical breakage except due to lightning (reverse polarity, over‐voltage due to external cause), the state ofthe internal control diode and of the inputs/output X and Y capacitors determine the warranty.
This warranty will not apply where the product has been misused, neglected, improperly installed, or repaired by anyone else than Victron Energy or one of its authorized Qualified Service Partners. In order to qualify for the warranty, the product must not be disassembled or modified.
Repair or replacement are our sole remedies and Victron Energy shall not be liable for damages, whether direct, incidental,special, or consequential, even caused by negligence or fault.
Victron Energy owns all parts removed from repaired products. Victron Energy uses new or reconditioned parts made by various manufacturers in performing warranty repairs and building replacement products. If Victron Energy repairs or replaces a part of a product, its warranty term is not extended. In case of replacement the new component has a warranty of 6 months, without effect on the initial warranty period. All remedies and the measure for damages are limited to the above. Victron Energy shall in no event be liable for consequential, incidental, contingent orspecial damages, even if having been advised of the probability of such damages. Any and all other warranties expressed or implied arising by law, course of dealing, course of performance, usage of trade or otherwise, including but not limited to implied warranties of merchantability and fitness for a particular purpose, are limited in duration to a period of two (2) years from the date of purchase.
Life Support Policy
As a general policy, Victron Energy, does not recommend the use of any of its products in life support applications where failure or malfunction of the Victron Energy's product can be reasonably expected to cause failure of the life support device or to significantly affect its safety or effectiveness. Victron Energy does not recommend the use of any of its products in direct patient care. Victron Energy will not knowingly sell its products for use in such applications unless it receives in writing assurances satisfactory to Victron Energy that the risks of injury or damage have been minimized, the customer assumes all such risks, and the Liability of Victron Energy is adequately protected under the circumstances.
As a product requires service, it must be brought back to the place of purchase. In case no contact can be taken with the merchant, or if he is either unable or not allowed to provide service, direct contact should be taken with Victron Energy.
Warranty on Repairs
The warranty period on products or on printed circuits boards repaired by Victron Energy as well as on printed circuit boards for replacement is 6 months from delivery by Victron Energy.
Transport
It is the responsibility of the sender to sufficiently package these products. The transport must be organized in a way to avoid any damage, especially when a single unit or heavy unit is sent.
Severability
If a part of the terms and conditions set out above is held invalid, void or unenforceable due to any particular national or international legislation, it shall not affect other parts of the terms and conditions remaining.
For Australia only
Our goods come with guarantees that cannot be excluded under the Australian Consumer Law. You are entitled to a replacement or refund for a major failure and compensation for any other reasonably foreseeable loss or damage. You are also entitled to have the goods repaired or replaced if the goods fail to be of acceptable quality and the failure does not amount to a major failure.
Exotronic provides high-quality products and solutions tailored for B2B and commercial customers, including commercial businesses, caravan manufacturers, marine electricians, OEMs, as well as emergency services, and more.